Mass transfer in electrolytic cells with gas stirring
Mass transfer to wall electrodes was investigated in a circular cell agitated by gas bubbles. Perforated and porous plates were used as gas spargers. Electrodes with varying height and electrolytic solutions having different physical properties were tested. It was found that the enhancing effect of...
Guardado en:
Autores principales: | , |
---|---|
Formato: | JOUR |
Materias: | |
Acceso en línea: | http://hdl.handle.net/20.500.12110/paper_0021891X_v17_n2_p340_Cavatorta |
Aporte de: |
Sumario: | Mass transfer to wall electrodes was investigated in a circular cell agitated by gas bubbles. Perforated and porous plates were used as gas spargers. Electrodes with varying height and electrolytic solutions having different physical properties were tested. It was found that the enhancing effect of gas bubbles on the mass transfer coefficient is a function of the gas hold-up, irrespective of the velocity of the gas flow and the gas distributor employed. The results were correlated for short mass transfer lengths by the relationship {Mathematical expression} and for fully developed mass transfer by {Mathematical expression} © 1987 Chapman and Hall Ltd. |
---|