Characterization of a quarter torus filter for vacuum arc ion flux transmission
Measurements on the ion flux transmission in a magnetically filtered d-c vacuum arc are presented. The device includes a metallic plasma-generating chamber with water-cooled electrodes coupled to a substrate chamber through a quarter-torus magnetic filter. It is employed a Copper cathode (6 cm in di...
Guardado en:
Autores principales: | , , |
---|---|
Formato: | Artículo publishedVersion |
Lenguaje: | Inglés |
Publicado: |
2004
|
Acceso en línea: | http://hdl.handle.net/20.500.12110/paper_01039733_v34_n4B_p1513_Kelly |
Aporte de: |
id |
paperaa:paper_01039733_v34_n4B_p1513_Kelly |
---|---|
record_format |
dspace |
spelling |
paperaa:paper_01039733_v34_n4B_p1513_Kelly2023-06-12T16:46:28Z Characterization of a quarter torus filter for vacuum arc ion flux transmission Braz. J. Phys. 2004;34(4 B):1513-1517 Kelly, H. Márquez, A. Pirrera, M. Measurements on the ion flux transmission in a magnetically filtered d-c vacuum arc are presented. The device includes a metallic plasma-generating chamber with water-cooled electrodes coupled to a substrate chamber through a quarter-torus magnetic filter. It is employed a Copper cathode (6 cm in diameter) with a Copper annular anode. The filter consists in a steel cylinder 500 mm length and 100 mm inner diameter with 90° of bending angle and corrugated lateral walls, surrounded by a magnetic field generating coil. The arc is operated at a current level of 100 A, and the intensity of the filtering magnetic field was in the range 0-200 G (measured at the knee of the filter). This magnetic field is enough high so as to magnetize the electrons but not the ions. The discharge is ignited by bringing (and later removing) a tungsten striker into contact with the cathode. The arc voltage drop, the floating potentials of the filter and the plasma, and the ion current collected by probes located at different positions as functions of the magnetic field intensity are reported and compared with measurements presented in the literature with other similar devices. Fil:Kelly, H. Universidad de Buenos Aires. Facultad de Ciencias Exactas y Naturales; Argentina. Fil:Márquez, A. Universidad de Buenos Aires. Facultad de Ciencias Exactas y Naturales; Argentina. Fil:Pirrera, M. Universidad de Buenos Aires. Facultad de Ciencias Exactas y Naturales; Argentina. 2004 info:eu-repo/semantics/article info:ar-repo/semantics/artículo info:eu-repo/semantics/publishedVersion application/pdf eng info:eu-repo/semantics/openAccess http://creativecommons.org/licenses/by/2.5/ar http://hdl.handle.net/20.500.12110/paper_01039733_v34_n4B_p1513_Kelly |
institution |
Universidad de Buenos Aires |
institution_str |
I-28 |
repository_str |
R-134 |
collection |
Biblioteca Digital - Facultad de Ciencias Exactas y Naturales (UBA) |
language |
Inglés |
orig_language_str_mv |
eng |
description |
Measurements on the ion flux transmission in a magnetically filtered d-c vacuum arc are presented. The device includes a metallic plasma-generating chamber with water-cooled electrodes coupled to a substrate chamber through a quarter-torus magnetic filter. It is employed a Copper cathode (6 cm in diameter) with a Copper annular anode. The filter consists in a steel cylinder 500 mm length and 100 mm inner diameter with 90° of bending angle and corrugated lateral walls, surrounded by a magnetic field generating coil. The arc is operated at a current level of 100 A, and the intensity of the filtering magnetic field was in the range 0-200 G (measured at the knee of the filter). This magnetic field is enough high so as to magnetize the electrons but not the ions. The discharge is ignited by bringing (and later removing) a tungsten striker into contact with the cathode. The arc voltage drop, the floating potentials of the filter and the plasma, and the ion current collected by probes located at different positions as functions of the magnetic field intensity are reported and compared with measurements presented in the literature with other similar devices. |
format |
Artículo Artículo publishedVersion |
author |
Kelly, H. Márquez, A. Pirrera, M. |
spellingShingle |
Kelly, H. Márquez, A. Pirrera, M. Characterization of a quarter torus filter for vacuum arc ion flux transmission |
author_facet |
Kelly, H. Márquez, A. Pirrera, M. |
author_sort |
Kelly, H. |
title |
Characterization of a quarter torus filter for vacuum arc ion flux transmission |
title_short |
Characterization of a quarter torus filter for vacuum arc ion flux transmission |
title_full |
Characterization of a quarter torus filter for vacuum arc ion flux transmission |
title_fullStr |
Characterization of a quarter torus filter for vacuum arc ion flux transmission |
title_full_unstemmed |
Characterization of a quarter torus filter for vacuum arc ion flux transmission |
title_sort |
characterization of a quarter torus filter for vacuum arc ion flux transmission |
publishDate |
2004 |
url |
http://hdl.handle.net/20.500.12110/paper_01039733_v34_n4B_p1513_Kelly |
work_keys_str_mv |
AT kellyh characterizationofaquartertorusfilterforvacuumarcionfluxtransmission AT marqueza characterizationofaquartertorusfilterforvacuumarcionfluxtransmission AT pirreram characterizationofaquartertorusfilterforvacuumarcionfluxtransmission |
_version_ |
1769810227070238720 |