Comparison of impurity profiles of Lipiblock® vs. Orlistat using HPLC and LC-MS/MS

Comparative HPLC-UV and LC-MS/MS studies of impurity profiles of a reference sample (Xenical®, F. Hoffmann-La Roche Ltd., Switzerland) vs. generic (Lipiblock®, EMS-Sigma Pharma, a generic drug) were carried out with ethanol extracts of commercial samples. The generic formulation contained higher lev...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Wagner, Vilegas, Severi, Juliana A., Wessjohann, Ludger A., Schneider, Alex
Formato: Articulo
Lenguaje:Inglés
Publicado: 2012
Materias:
Acceso en línea:http://sedici.unlp.edu.ar/handle/10915/8434
http://www.latamjpharm.org/resumenes/31/1/LAJOP_31_1_1_14.pdf
Aporte de:
Descripción
Sumario:Comparative HPLC-UV and LC-MS/MS studies of impurity profiles of a reference sample (Xenical®, F. Hoffmann-La Roche Ltd., Switzerland) vs. generic (Lipiblock®, EMS-Sigma Pharma, a generic drug) were carried out with ethanol extracts of commercial samples. The generic formulation contained higher levels of common impurities as well as a considerable number of impurities not found in the reference product. The detected impurity profile of Lipiblock® revealed that it most likely is based on fermentation. Since the effect of the impurities is unknown, at this point fully synthetic Xenical® appears to offer a better safety margin than Lipiblock® which, however, compares quite well to other generic formulations.