High-resolution TDPAC measurement in K₂ZrF₆

A time resolution of 2τ=0.75 ns, achieved with a conventional TDPAC setup with FCs detectors, allowed a determination of the very high electric field gradient at Hf impurity sites in K<sub>2</sub>ZrF<sub>6</sub>. Simple theoretical calculations seem to indicate that nearest n...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Martínez, Jorge Alberto, Rodríguez, Agustín Mario, Caracoche, María Cristina, Mercader, Roberto Carlos, López García, Alberto Raúl
Formato: Articulo
Lenguaje:Inglés
Publicado: 1981
Materias:
Acceso en línea:http://sedici.unlp.edu.ar/handle/10915/132965
Aporte de:
Descripción
Sumario:A time resolution of 2τ=0.75 ns, achieved with a conventional TDPAC setup with FCs detectors, allowed a determination of the very high electric field gradient at Hf impurity sites in K<sub>2</sub>ZrF<sub>6</sub>. Simple theoretical calculations seem to indicate that nearest neighbours are responsible for the interaction observed.