Kinetics of the anodic dissolution of iron in concentrated ionic media : Galvanostatic and potentiostatic measurements

The anodic dissolution of iron has been studied in concentrated aqueous media by determining potential/current curves using potentiostatic and galvanostatic techniques. The results indicate that the most likely value of Tafel slope in the range of pH from 0 to 5 is 2·3 (2RT/3F) for the anodic reacti...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Podestá, José J., Arvia, Alejandro Jorge
Formato: Articulo
Lenguaje:Inglés
Publicado: 1965
Materias:
Acceso en línea:http://sedici.unlp.edu.ar/handle/10915/121855
Aporte de:
Descripción
Sumario:The anodic dissolution of iron has been studied in concentrated aqueous media by determining potential/current curves using potentiostatic and galvanostatic techniques. The results indicate that the most likely value of Tafel slope in the range of pH from 0 to 5 is 2·3 (2RT/3F) for the anodic reaction. The agreement between the two techniques is good. Among the various mechanisms proposed for the reaction, the results are interpreted satisfactorily by means of the reaction scheme recently proposed by Bockris et al.