Bisphosphonates study on effect of implant-bone interface

Introduction: The success of any dental implant depends on a number of parameters including general health conditions, biocompatibility of implant materials, the nature of the surface of the microscopic and macroscopic implant, the surgical procedure and the quality and quantity of bone maxilla. Obj...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Brunengo, Ignacio, Virga, María Carolina, Aguzzi, Alejandra, Sosa, Federico, Marion, Gustavo Carlos
Formato: conferenceObject
Lenguaje:Inglés
Publicado: 2021
Materias:
Acceso en línea:http://hdl.handle.net/11086/21622
Aporte de:
id I10-R14111086-21622
record_format dspace
institution Universidad Nacional de Córdoba
institution_str I-10
repository_str R-141
collection Repositorio Digital Universitario (UNC)
language Inglés
topic Implantación dental
Implantes dentales
Alendronato
Difosfonatos
spellingShingle Implantación dental
Implantes dentales
Alendronato
Difosfonatos
Brunengo, Ignacio
Virga, María Carolina
Aguzzi, Alejandra
Sosa, Federico
Marion, Gustavo Carlos
Bisphosphonates study on effect of implant-bone interface
topic_facet Implantación dental
Implantes dentales
Alendronato
Difosfonatos
description Introduction: The success of any dental implant depends on a number of parameters including general health conditions, biocompatibility of implant materials, the nature of the surface of the microscopic and macroscopic implant, the surgical procedure and the quality and quantity of bone maxilla. Objective: to evaluate the alkaline phosphatase (AP) levels to analyze the therapeutic response to treatment with bisphosphonates administered subcutaneously in experimental animals. Materials and Methods: The pharmaceutical formulations were prepared with a dosage for Alendronate (AL) of 0.5 mg / kg weight, and pamidronate (PA) of 0.6 mg / Kg . Control (C) was saline. The effect was evaluated in normal male Wistar rats, which were divided into three groups, one control and two problems. We designed a class IV titanium microimplant dimensions 1 mm diameter by 2 mm to place in rat tibia after a drilling operation with strawberry No.6 manual rotation. AP in blood was measured to analyze bone level changes. Comparison of the data was performed by analysis of variance of two criteria (treatments and treatment times: 0, 15, 30, 60 and 90 days). Differences were considered significant if p <0.05. Results: The average value obtained in pubertal rats was 1425 IU / I, and in normal adult rats taken as a parameter for estimating the bone marker normal values in rats was 51.03 IU / l. The data showed that the experimental groups at 15 days 1.37 higher PA than AL; 30 days PA is 1.12 higher than Al, at 60 days 1, 14 and 90 days increased 1.07 higher. Conclusions: The experimental model healthy male rats subcutaneously weekly treatment with AL and PA for 12 weeks resulted in significant variations in mineral concentrations in blood, revealing an inhibitory action on osteoclast activity by the drugs studied .
format conferenceObject
author Brunengo, Ignacio
Virga, María Carolina
Aguzzi, Alejandra
Sosa, Federico
Marion, Gustavo Carlos
author_facet Brunengo, Ignacio
Virga, María Carolina
Aguzzi, Alejandra
Sosa, Federico
Marion, Gustavo Carlos
author_sort Brunengo, Ignacio
title Bisphosphonates study on effect of implant-bone interface
title_short Bisphosphonates study on effect of implant-bone interface
title_full Bisphosphonates study on effect of implant-bone interface
title_fullStr Bisphosphonates study on effect of implant-bone interface
title_full_unstemmed Bisphosphonates study on effect of implant-bone interface
title_sort bisphosphonates study on effect of implant-bone interface
publishDate 2021
url http://hdl.handle.net/11086/21622
work_keys_str_mv AT brunengoignacio bisphosphonatesstudyoneffectofimplantboneinterface
AT virgamariacarolina bisphosphonatesstudyoneffectofimplantboneinterface
AT aguzzialejandra bisphosphonatesstudyoneffectofimplantboneinterface
AT sosafederico bisphosphonatesstudyoneffectofimplantboneinterface
AT mariongustavocarlos bisphosphonatesstudyoneffectofimplantboneinterface
bdutipo_str Repositorios
_version_ 1764820394671341570